Chart boundary

Does not calculate charging time, guarantee vehicle range, approve EVSE current, account for all vehicle efficiency, or replace the EV charging-time calculator.

ev recovery curve

Overnight energy recovery bands

The curve compares 8, 10, and 12 hour energy windows before losses, then hands exact range and battery inputs to the calculator.

Scopeev and service capacityX-axisEVSE current at homeY-axisrough kWh recovered before lossesReviewAnnualNextEV charging time calculator
Overnight energy recovery bandsEVSE current at homeEVSE current at homerough kWh recovered before lossesrough kWh recovered bef...8 h window8 h windowenergy bandenergy band10 h window10 h windowenergy bandenergy band12 h window12 h windowenergy bandenergy bandRange handoffRange handoffvehicle efficiencyvehicle efficiency
The curve compares 8, 10, and 12 hour energy windows before losses, then hands exact range and battery inputs to the calculator.
Overnight energy recovery bands12A/120V12A/120V16A16A32A32A48A48A12 h12 h10 h10 h8 h8 hEVSE current at homeEVSE current at homerough kWh recovered before lossesrough kWh recove...
12 A at 120 Vabout 12-17 kWh over 8-12 h

Slow recovery; practical for modest daily driving.

16 A at 240 Vabout 31-46 kWh over 8-12 h

Lower-current Level 2 with useful overnight energy.

32 A at 240 Vabout 61-92 kWh over 8-12 h

Common Level 2 planning band before charger losses.

48 A at 240 Vabout 92-138 kWh over 8-12 h

High home current with more service-capacity pressure.

Decision table

Show approximate kWh recovered over fixed overnight windows before users enter exact battery, charger, efficiency, and distance values.

Scroll sideways to keep row labels aligned with hidden columns.

Basis: NRCan EV charger basics and Canadian EV owner questions about charging current and 100 A services.
Charging settingRough power8 h kWh10 h kWh12 h kWhHandoff
12 A at 120 VAbout 1.4 kW before losses11.514.417.3EV charging time calculator
16 A at 240 VAbout 3.8 kW before losses30.738.446.1EVSE current calculator
32 A at 240 VAbout 7.7 kW before losses61.476.892.2Service capacity review
48 A at 240 VAbout 11.5 kW before losses92.2115.2138.2Panel upgrade vs load management chart
Notes
  • Treat this chart as a planning and conversation aid only.
  • Confirm current utility requirements, product markings, manufacturer instructions, and local authority requirements before field work.
  • Use the linked calculator or table when the task needs project-specific arithmetic.

Source links

Open the underlying public sources before treating the chart as project guidance.