Voltage system context

Use the system label to choose the right calculator preset before doing project-specific arithmetic.

Scopevoltage systemsX-axisnominal utilization voltageY-axiscommon system contextReviewAnnualNextVoltage drop calculator
Voltage system context120 V / 240 V120 V /240 VSingle-phase branchSingle-phasebranchUse for many residential and small-load presets.Use for many re...120/208 V120/208 VCommercial wyeCommercial wyeSeparate line-neutral and line-line loads before calculating.Separate line-n...347/600 V347/600 VCanadian industrialCanadianindustrialCommon for larger commercial and industrial distribution.Common for larg...Measured or specified voltageMeasured or spec...Project checkProject checkThe nominal label is not a service approval.The nominal lab...
Use the system label to choose the right calculator preset before doing project-specific arithmetic.
120 V / 240 VSingle-phase branch
  • Use for many residential and small-load presets.
120/208 VCommercial wye
  • Separate line-neutral and line-line loads before calculating.
347/600 VCanadian industrial
  • Common for larger commercial and industrial distribution.
Measured or specified voltageProject check
  • The nominal label is not a service approval.
Single-phase branch120 V / 240 V
Commercial wye120/208 V
Canadian industrial347/600 V
Project checkMeasured or specified voltage

Decision table

Show common nominal voltage systems and calculator preset context.

Scroll sideways to keep row labels aligned with hidden columns.

Common Canadian nominal system categories prepared for calculator presets; utility-specific service requirements are outside this page.
Nominal systemPhaseCommon contextCalculator presetField note
120 VSingle-phase loadLighting, receptacles, controls, and small equipment120 V single-phase loadOften derived from a 120/240 V or 120/208 V system.
120/240 VSingle-phase, 3-wireDetached houses and many small services240 V single-phase line-to-lineUse the actual load voltage in a calculation.
120/208 VThree-phase, 4-wire wyeCommercial buildings and multi-unit residential distribution208 V three-phase or 120 V line-to-neutralLine-to-line and line-to-neutral loads need different voltage inputs.
347/600 VThree-phase, 4-wire wyeCanadian commercial and industrial distribution, including some lighting and mechanical loads600 V three-phase or 347 V line-to-neutralConfirm equipment ratings and local rules before applying.
600 VThree-phase loadIndustrial motors, distribution, and larger equipment600 V three-phaseDo not infer fault current, protection, or conductor ampacity from voltage alone.
Notes
  • The chart is a routing and planning aid, not a utility service standard.
  • Always confirm the actual service and utilization voltage for the project.
  • Some installations use other systems or utility-specific service arrangements.